Imaging Systems Manufacturer, Suppliers and Exporter in Ambala
Ambala Science Lab is leading Imaging Systems Manufacturer,and supplier and Exporter in Ambala India, Algeria (Algiers), Angola (Luanda), Argentina (Buenos Aires), Armenia (Yerevan), Australia(Canberra), Austria (Vienna), Bahrain (Manama), Bangladesh (Dhaka), Bhutan (Thimphu), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Montenegro (Podgorica), Morocco (Rabat), Mozambique (Maputo), Myanmar (Naypyidaw), Namibia (Windhoek), Nepal (Kathmandu), New Zealand (Wellington), Nigeria (Abuja), Oman (Muscat), Palestine (Ramallah), Panama (Panama City), Papua New Guinea (Port Moresby), Paraguay (Asunción), Peru (Lima), Philippines (Manila)¸ Portugal (Lisbon), Qatar (Doha), Rwanda (Kigali), Saudi Arabia (Riyadh), Senegal (Dakar), Serbia (Belgrade), Sierra Leone (Freetown), Slovakia (Bratislava), South Africa (Cape Town) (Pretoria) (Bloemfontein), South Sudan (Juba), Spain (Madrid), Sri Lanka (Sri Jayawardenepura Kotte) (Colombo), Sudan (Khartoum), Syria (Damascus), Tanzania (Dodoma), Thailand (Bangkok), Togo (Lomé), Tonga (Nuku'alofa), Trinidad and Tobago (Port of Spain), Tunisia (Tunis), Turkey (Ankara), Turkmenistan (Ashgabat), Uganda (Kampala), United Arab Emirates (Abu Dhabi), United Kingdom (London), United States (Washington, D.C.)
Last updated: 17 October 2026
Gel imaging equipment makes stained DNA and protein bands visible and records them. Ambala Science Lab lists 7 imaging items in this family, supplied from Ambala Cantt, Haryana, India: three UV transilluminators, a blue-LED transilluminator, a white and blue LED light box, a student-assembled fluorescence viewer, and a complete stand-alone gel documentation system with a 302 nm UV transilluminator, camera and printer.
What this range contains
The main choice is UV or blue light. UV transilluminators are used with ethidium bromide and need UV protection for eyes and skin; blue-light units excite green DNA stains and avoid UV exposure. Only two items publish a wavelength (the Blue LED Light Transilluminator at 465 nm and the Imaging System at 302 nm), and none of the mains-powered units publishes a mains input.
Specifications compared
Every value below is the figure published on that item's own product listing. Not published means the catalogue does not state that figure, so confirm it in writing before ordering.
Product | Type | Light source | Wavelength | Viewing area | Documentation | Power |
UV transilluminator, compact | Four 6 W bulbs | Not published | 16.5 x 13.5 cm, scratch resistant for band excision with a metal blade | Not published | Not published | |
Blue-LED transilluminator | Blue LED | 465 nm | Not published | Two-position amber emission filter cover, fully removable for documentation | Not published | |
UV transilluminator, dual intensity | Array of high-intensity UV bulbs with an optimised filter | Not published | 16 x 19 cm | Not published | Dual-intensity switch, 50 per cent or 100 per cent | |
UV transilluminator, benchtop high output | Four 25 W ultraviolet tubes | Not published | Not published | Not published | 100 W | |
Student-assembled fluorescence viewer kit | Not published | Not published | Not published | Not published | One 9 V battery, not included | |
Dual white and blue LED gel viewing box | Dual LEDs, stated to be long-lasting | Not published | Not published | Compatible with mobile phones and smart devices | Not published | |
Gel documentation imaging system, stand-alone | 302 nm | 302 nm | 7-8/10 x 7-8/10 in | 10-megapixel digital camera with zoom lens and power adapter; runs on batteries or power cord | Not published |
Choosing a viewer
Safest option for a school laboratory: the Blue LED Light Transilluminator emits at 465 nm to excite most green nucleic acid stains, with a two-position amber filter cover that removes fully for documentation. The LED Light Box switches between white and blue light, includes a filter for the blue setting and works with mobile phones for gel photographs.
UV viewing and band cutting: the Compact UV Transilluminator (four 6 W bulbs, 16.5 x 13.5 cm scratch-resistant filter glass, hinged UV-blocking cover) suits a mid-sized gel; the UV Transilluminator (16 x 19 cm black-glass surface, 50 or 100 per cent intensity) takes large gels; the UVP Benchtop Transilluminator has four 25 W tubes for 100 W total output in a stainless-steel frame.
Gel documentation without a computer: the Imaging System combines a 302 nm transilluminator with a 7-8/10 in square viewing area, a metal hood, a 10-megapixel camera and a colour printer for 4 x 6 in prints, with consumables for 108 prints.
Teaching how fluorescence works: the Molecular Fluorescence Viewer is built by students from a kit, makes one viewer, and runs on a 9 V battery that is not included.
What to confirm before you order
Specification to confirm | Why it matters |
UV wavelength | The Compact UV, UV and UVP Benchtop transilluminators publish no wavelength. 302 nm and 365 nm units behave differently with stains and DNA, so confirm the wavelength before ordering. |
UV protection | UV exposure harms eyes and skin. UV-blocking covers are published on the three UV transilluminators and a UV-blocking viewport on the Imaging System. Order UV-protective face shields or eyewear for anyone working at an open UV surface. |
Mains input | No mains voltage is published for any of the mains-powered units. Confirm 230 V, 50 Hz operation for a 220-240 V market. |
Stain compatibility | Blue-light units suit green DNA stains; the Blue LED Light Transilluminator can also excite ethidium bromide. Confirm the stain you will use against the viewer. |
Camera filter | The Imaging System includes a filter for viewing gels stained with ethidium bromide. Confirm a suitable filter if you will photograph green-stained gels. |
Warranty and spare lamps | No warranty period or spare bulb and tube supply is published. Confirm both, especially for the UV units. |
Who buys this range
College and university biotechnology, microbiology and life science departments, research and diagnostic training laboratories, higher secondary school biology laboratories, and government buyers purchasing against a tender or rate contract. Ambala Science Lab supplies this range from Ambala Cantt to buyers in India and export markets in East Africa, Africa, Europe, the Middle East and Asia. Bulk and tender quantities, and buyer branding on products, packaging and manuals, are handled through lab tenders and OEM orders.
Related ranges
Range | How it relates |
The equipment group this family belongs to | |
Gel tanks and casting accessories | |
Electrophoresis power supplies | |
Bundled electrophoresis lab stations | |
Practical kits that use this equipment | |
The parent biotechnology range | |
Quotations against a tender or bill of quantities |
Frequently asked questions
Which imaging items are in this range?
Seven: Compact UV Transilluminator, Blue LED Light Transilluminator, UV Transilluminator, UVP Benchtop Transilluminator, Molecular Fluorescence Viewer, LED Light Box and Imaging System.
Should a school choose UV or blue light?
Blue light avoids UV exposure and works with green DNA stains, which makes the Blue LED Light Transilluminator or the LED Light Box the safer choice for a teaching laboratory. UV units are used with ethidium bromide and need UV protection.
Which items can document gels without a computer?
The Imaging System includes a 10-megapixel camera and a colour printer and needs no computer. The LED Light Box is compatible with mobile phones, and the Blue LED Light Transilluminator filter cover removes fully for photographs.
What wavelengths are published?
465 nm for the Blue LED Light Transilluminator and 302 nm for the Imaging System. The other UV transilluminators publish no wavelength, so confirm it before ordering.
What is the Molecular Fluorescence Viewer?
A kit from which students build one battery-powered fluorescence viewer and then use it to see molecules fluoresce. It runs on a 9 V battery, which is not included.
Can imaging equipment be supplied against a tender?
Yes. State UV or blue light, the wavelength, gel size, whether a camera or printer is needed, your mains voltage and frequency and the quantity.
Request a quotation
Send the product names, the quantity per item, the destination and your mains voltage and frequency. Ambala Science Lab, Near GPO, 110, The Mall, Ambala Cantt - 133001, Haryana, India. Email [email protected] or use the contact page. Ordering questions are answered on the FAQ page.
Compact UV Transilluminator
Product Code : EL-IS-10930
Compact UV transilluminator: four 6 W bulbs, 16.5 x 13.5 cm scratch-resistant filter glass, hinged UV-blocking cover. Emission wavelength to be confirmed.
Note:
View Details
Blue LED Light Transilluminator
Product Code : EL-IS-10931
Blue-LED transilluminator at 465 nm for green DNA stains, two-position amber filter cover. Avoids UV; viewing surface size to be confirmed.
Note:
View Details
UV Transilluminator
Product Code : EL-IS-10932
UV transilluminator: 16 x 19 cm black-glass surface, dual-intensity 50/100 per cent switch, angling UV-blocking cover. Wavelength to be confirmed.
Note:
View Details
UVP Benchtop Transilluminator
Product Code : EL-IS-10933
Benchtop UV transilluminator: four 25 W tubes, 100 W total, stainless-steel frame, adjustable UV-blocking cover. Wavelength and surface size to be confirmed.
Note:
View Details
Molecular Fluorescence Viewer
Product Code : EL-IS-10934
Student-assembled battery-powered fluorescence viewer. Materials for one viewer; 9 V battery not included. One kit per student group.
Note:
View Details
LED Light Box
Product Code : EL-IS-10935
Dual white and blue LED gel viewing box in moulded polymer, filter included, phone-compatible. Blue mode avoids UV; wavelength to be confirmed.
Note:
View Details
Imaging System
Product Code : EL-IS-10936
Stand-alone gel documentation package: 302 nm transilluminator, 10 MP camera, metal hood, colour printer with consumables for 108 prints. No computer needed.
Note:
View Details